Place of Origin:
China
Brand Name:
DUBHE
Certification:
ISO 9001
Model Number:
PCG-20
Industrial wastewater rarely arrives at a comfortable, constant condition. pH swings with batch discharge, temperature rises in summer and falls in winter, and a carrier that performs well in a pilot at 25 °C can deform, hydrolyse or lose porosity in real service. These polymer composite gel biocarriers are specified to hold their geometry and performance across pH 6 to 10 and a working temperature range of 1 to 50 °C.
That tolerance is a property of the cross-linked polymer composite matrix rather than of the water around it. The gel resists hydrolysis in mildly alkaline conditions, does not collapse at the cold end of the range, and does not soften or swell beyond design size at the warm end. Porosity stays at 98%, surface area stays above 15,000 m²/m³, and the cube keeps its 20 mm working size, so dosing calculations remain valid season after season and treatment performance does not drift with the weather or the production schedule.
Technical Specifications| Item | Specification |
|---|---|
| Material | Polymer composite gel (hydrophilic hydrogel) |
| Shape | Cube |
| Size | 20 ± 2 mm (hydrated state) |
| Bulk Count | 125,000 pcs/m³ |
| Specific Surface Area (BET) | ≥ 15,000 m²/m³ |
| Protected Specific Surface Area | ≥ 5,000 m²/m³ |
| Porosity | 98% |
| Dosing Rate | 5–25% |
| Allocation Ratio | 10–30% |
| Biofilm Hanging Time | 3–7 days |
| Applicable pH | 6–10 |
| Working Temperature | 1–50 °C |
| Density | 12.5 ± 0.75 dry-kg / wet-m³ |
| Service Life | ≥ 10 years |
Q: What happens if pH drifts outside 6 to 10 for a short period?
A: Short excursions are tolerated because the matrix is cross-linked and only slowly affected, but sustained operation outside the stated range accelerates ageing and should be corrected by neutralisation or equalisation. The quoted window is the range over which design life and mechanical performance are guaranteed.
Q: Does cold water reduce treatment performance?
A: Biological activity slows in cold water for any process, but the carrier itself does not lose porosity, surface area or structural integrity down to 1 °C. Because biomass is protected inside the matrix, the plant recovers quickly when temperature rises again, rather than losing its population.
Q: Why does a stable 20 mm size matter commercially?
A: Because dosing, screen sizing and mixing energy are all calculated from working size and density. A carrier that swells or compacts changes those values over time; a dimensionally stable carrier keeps the original design valid for its full ten year life.